Then apply standard asphalt shingles over the membrane.
Low slope roof section.
For buildings with low slope roofs less than 2 12 slope the wind speed at eave height is used.
A 3 per foot slope is considered low but may be acceptable if a double layer of felt is used.
These panels generally come with a painted mill finish or a clear acrylic finish.
Vertical end laps should be at least 3 inches and horizontal laps 6 inches.
Roof fast 95 base iko roof fast 95 base is a self adhesive product that can easily be cold applied on low slope roofs.
Roof coverings installed on low slope roofs roof slope 2 12 in accordance with section 1507 shall resist impact damage based on the results of tests conducted in accordance with astm d3746 astm d4272 cgsb 37 gp 52m or the resistance to foot traffic test in section 5 5 of fm 4470.
That includes soldered metal roofing or synthetic membranes.
The reason water ponds on a low slope roof is a possible misinterpretation of the 1 4 in 12 minimum slope by the building code.
The usual slope for asphalt shingles is a 4 or greater rise for every horizontal foot of run.
For a low slope residential roof there are two main options.
By low slope roofing we mean any roof that is pitched at less than 4 inches of rise in 12 inches of run or 4 12 pitch.
The only function the three tab shingles perform at that low a slope is decorative that s a legitimate use of shingles when you wish to preserve a consistent appearance but they do not function as a weather barrier in such installations that function is being performed it s being performed at all by the underlayment and or flashing below the shingles which in this case must be a material with self sealing properties to prevent water intrusion at the shingle s fasteners.
Low slope roofs present special challenges in terms of preventing unique types of damage.
Significant insight may be found in asce 7 section 8 4 as referenced in ibc section 1611 2.
Iko roof fast low slope roofing components are engineered and manufactured to meet those particular challenges.
1 3 5 design pressure coefficients for roof zones wind produces different magnitudes of pressure acting on the surfaces of a building due to the building s geometry and can create small areas of higher pressure on a surface while at the same time other areas on the same surface experience lower pressures.
In areas with extensive snowfall or windblown rain the best protection against leakage is to cover the entire low slope roof area with a bituminous membrane as shown in figure 2 4.
The membrane will outlast the shingles and seal around all nail penetrations.
1 cover the entire surface with a self adhesive flashing membrane such as grace ice water shield there are many equivalent products.
Low slope structural roofing generally used on roof pitches ranging from 12 to 3 12 consists of interlocking panels commonly called standing seam roofing that run vertically along the roof surface.